Construction:

4x20AWG Power Cable Conductor 20AWG stranded tinned copper wire Insulation XLPE. Nominal outer diameter is 1.5mm Insulation Color 2xBlack and 2xWhite

2x24AWG Signal Conductor Conductor 24AWG stranded tinned copper wire Insulation XLPE. Nominal outer diameter is 1.1mm Insulation Color Red and Black

2Cx9/125um Tight Buffered Fiber Cable Tight buffered fiber Single-mode fiber meets the ITU G.652D specification Strength meber Aramid yarn Sheath PVC, Nominal outer diameter: 1.6mm Sheath Color Blue & yellow

Element Assembly Central Strength Member 1.5mm steel wire coated with PE, OD: 2.1mm Wrapping Tape Water blocking tape Screen Tinned copper wire braiding, 90% coverage Inner Jacket Black TPU Armor Steel wire braid, dia. 0.2mm, coverage 80% Sheath TPU, nominal outer diameter 12.0mm. Sheath Color Black Cable Weight 250kg/km

Optical Characteristics Parameter Standard Single Mode Fiber per ITU-T G.652D Non-zero Dispersion Shifted fiber per ITU-T G.655 Non-zero Dispersion Shifted fiber per ITU-T G.656 Units Fiber Code 9 8 7 Attenuation, Loose Tube Cables @1310nm ≤0.35 N/A N/A dB/km @1550nm ≤0.22 ≤0.22 ≤0.22 dB/km @1625nm ≤0.25 ≤0.26 ≤0.26 dB/km Attenuation, Tight Buffer or Semi-Tight Cables @1310nm ≤0.38 N/A dB/km @1550nm ≤0.28 N/A dB/km Chromatic Dispersion between 1260 and 1360nm (O Band) ≤3.5 N/A N/A ps/(nm*km) between 1460 and 1530nm (S Band) N/A N/A 2.0-7.0 ps/(nm*km) between 1530 and 1565nm (C Band) ≤18 1.0-10.0 7.0-10.0 ps/(nm*km) between 1565 and 1625nm (L Band) ≤22 7.0-12.0 10.0-14.0 ps/(nm*km) Zero Dispersion Wavelength 1310±11 1530-1560 1460-1565 nm Zero Dispersion Slope 0.093 0.093 0.093 ps/(nm2.km) Point Discontinuity at 1300nm& 1550nm 0.1 0.1 0.1 dB Mode Field Diameter @1300nm 9.3±0.5 N/A N/A um @1550nm 10.4±0.8 8.5±0.6 9.0±0.5 um Cable Cut-offWavelength ≤1260 ≤1450 ≤1450 nm PMD (Individual fiber) ≤0.2 ≤0.2 ≤0.2 ps/km1/2 Cladding Diameter 125±1 125±1 125±1 um Core/Cladding Concentricity Error ≤0.5 ≤0.5 ≤0.6 um Cladding Non-Circularity ≤1.0 ≤1.0 ≤1.0 % Coating Non-Circularity ≤6.0 ≤6.0 ≤6.0 % Primary Coating Diameter 245±10 245±10 245±10 um Proof-Test Level 100 (0.7) 100 (0.7) 100 (0.7) Kpsi/GN/m2 Fatigue Coefficient ≥20 ≥20 ≥20 Temperature Dependence between 0°C ~ +70°C @ 1310 & 1550nm 0.1 0.1 0.1 Db/km

The fibers contain no splices.

Electrical Properties @20°C:

20AWG Power Cable

Conductor Resistance @ 20°C : 35.3 ohm/km

Insulation Resistance: ≥10GOhmxkm

24AWG Signal Conductor

Conductor Resistance @ 20°C: 95Ohm/km

Insulation Resistance: ≥10GOhmxkm

Mechanical Properties:

Max. Pulling Load

  1. Under installation: 1500N

  2. In service: 600N

Maximum Compressive Load: 1000N Minimum Bending Radius:

  1. Under installation: 20×OD

  2. During operation: 10×OD.